RS485 communications cable (connected to a terminal block; recommended), Recommended: a multi-paired, individually foil shielded cable that complies with local standards and M6 OT terminals, RS485 communications cable (connected to a network port), Recommended: a CAT 5E outdoor shielded network cable with the internal resistance ≤ 1.5 ohms/10 m (1.5 ohms/393.70 in. To obtain better user experience, upgrade the browser to the latest version. All or part of the products, services and features described in this document may not be within the purchase scope or the usage scope. To obtain better user experience, upgrade the browser to the latest version. For the best experience on our site, be sure to turn on Javascript in your browser. SUN2000-(90KTL, 95KTL, 100KTL, 105KTL) Series User Manual. Enterprise products, solutions & services, Products, Solutions and Services for Carrier, Phones, laptops, tablets, wearables & other devices, Network Management, Control, and Analysis Software, Data Center Storage Consolidation Tool Suite, Huawei CloudLink Video Conferencing Platform, One-stop Platform for Marketing Development, City of Enterprise products, solutions & services, Products, Solutions and Services for Carrier, Phones, laptops, tablets, wearables & other devices, Network Management, Control, and Analysis Software, Data Center Storage Consolidation Tool Suite, Huawei CloudLink Video Conferencing Platform, One-stop Platform for Marketing Development, City of Current per MPPT: 26 A: Max. Produktvorteile: • Höherer DC Eingangsstrom. Huawei Inverter SUN2000-100KTL-M1 have a protection degree of IP66, making them dust free and water resistant. I agree to receive email notifications from the Huawei Enterprise Support Community and I understand that I can unsubscribe at any time. LG batteries cannot be connected in cascading scenarios. Zudem sind alle neuen hauseigenen Optimierer-Modelle als optionales Zubehör möglich. Tip, coordinate the inverter warranty with the warranty of the solar panels. Huawei shall not bear any responsibility for translation accuracy and it is recommended that you refer to the English document (a link for which has been provided). Manual. The RS485 communication distance between the SUN2000 at the end of the daisy chain and the SmartLogger cannot exceed 1000 meters. Blinkt grün in langen Abständen (1 s lang ein und 1 s lang aus) Das Mobiltelefon ist mit dem SUN2000 verbunden. (Wenn ein Mobiltelefon an den SUN2000 angeschlossen ist, zeigt die Anzeige zunächst an, dass das Telefon an den SUN2000 angeschlossen ist): Blinkt grün in langen Abständen.) Yesterday I started my home assistant project by integrating my Huawei PV system. Login. Huawei shall not bear any responsibility for translation accuracy and it is recommended that you refer to the English document (a link for which has been provided). Some functions of the website may be unavailable. If RS485 is selected, connect an RS485 communications cable to the SUN2000, but the AC power cable does not need to connect to a SmartLogger that supports MBUS. This document describes the SUN2000-3KTL-M0, SUN2000-4KTL-M0, SUN2000-5KTL-M0, SUN2000-6KTL-M0, SUN2000-8KTL-M0, and SUN2000-10KTL-M0 in terms of their installation, electrical connections, commissioning, maintenance, and troubleshooting. This allows insight into individual strings and exposes possible errors. The SUN2000 can connect to the SmartLogger to implement RS485 communication. Huawei FusionSolar provides new generation string inverters with smart management technology to create a fully digitalised Smart PV Solution. solutions. User Guide. Efficiency Test under All Scenarios, 98.8% (@480V) Max. Single-core outdoor copper cable and M8 OT/DT terminal. Used for connecting to the RS485 signal ports of the battery and smart power sensor. From Strategy to Execution, Global Service The RS485 communication distance between the SUN2000 at the end of the daisy chain and the SmartLogger cannot exceed 1000 meters. Huawei_SUN2000-100KTL-M1_VDE-AR-N-4105-2018-EZE Huawei_SUN2000-100KTL-M1_VDE-AR-N-4105-2018-NA VDE4110-4120 . Access to the Modbus interface is established by connecting to the device's internal Wifi access point. It is handling an ethernet cable connection or a WiFi to your . Copyright © Huawei Technologies Co., Ltd. 2020. shell bash client api-gateway api-client solar huawei solar-energy inverter openapi-account huawei-fusionsolar sun2000. • Huawei App Store (Android) • Google Play (Android) • App Store (iOS) Der Router unterstützt das WLAN-Protokoll (IEEE 802.11 b/g/n, 2,4 GHz), und das WLAN-Signal erreicht den SUN2000L. No relevant resource is found in the selected language. SUN2000-100KTL-H1. The MBUS (PLC) technology transmits communication signals over power cables through a communications board. Professionals . If the SUN2000-36KTL adopts FE communications mode, it supports only RS485 and FE communications modes, and does not support MBUS (PLC) communications mode. Office. SUN2000-(50KTL, 60KTL, 65KTL)-M0 User Manual. (Optional) Registering an Installer Account, (Optional) Setting the Physical Layout of the Smart PV Optimizers, IPS Check (for Italy CEI0-21 Grid Code Only), SUN2000L-(2KTL-5KTL) and SUN2000-(2KTL-6KTL)-L1 Battery and Smart Power Sensor Quick Guide. JavaScript seems to be disabled in your browser. The device can intelligently monitor 20 strings, reach an efficiency rating of 98,6% (98,4% European efficiency) at 400Vac, has 10 MPPTs and has various characteristics that make it safe and reliable. Input Voltage : 1,500 V: Max. Purpose. When laying out signal cables, separate them from power cables and keep them away from strong interference sources to prevent communication interruption. If you want to make an order in our webshop, please log in or request an account. Aus. C10_11 (HV) Cert_BV C10_11 (LV) . Ensure that the baud rates of the DDSU666-H and YDS70-C16 meters are set to the default values. Es besteht keine Kommunikation. The SUN2000 has a residual current monitoring unit (RCMU) inside. -25°C to +60°C (derated when the temperature is higher than 45°C) Operating humidity. We will help you learn how we collect, use, store and share your personal information and the rights you have in accordance with. Only one LG battery is supported, and the LG battery must be connected to the inverter equipped with the Smart Dongle. If not, contact the local power operator. You do not need to separately prepare a PE cable. This manual comes under the category not categorized and has been rated by 1 people with an average of a 8.4. The Sun2000 5KTL M1 has an output voltage of 5 kW. Dimensions (W x H x D, mm) 525 x 470 x 166 (including only the rear mounting kit of the SUN2000) Weight. Instantly find the answers to all your questions about Huawei products and Leave your details and we'll be in touch. If multiple SUN2000s are used, connect all the SUN2000s in daisy chain mode over an RS485 communications cable. Instantly find the answers to all your questions about Huawei products and Used for connecting to the DI2 positive signal. The surplus core should be cut off from the protection layer. All or part of the products, services and features described in this document may not be within the purchase scope or the usage scope. Stories, Digital Transformation: Ensure that the protection layer of the cable is in the connector. Maximum short-circuit current (per MPPT) No battery connected: 18 A. LG-RESU battery connected: 15 A. When both battery and power meter are configured, they need be crimped to the 485B2 and 485A2 ports. Properly plan the installation position of optimizers to ensure that the cables between the optimizer, and the PV module and between adjacent optimizers can be properly connected, and the. Enterprise products, solutions & services, Products, Solutions and Services for Carrier, Phones, laptops, tablets, wearables & other devices, Network Management, Control, and Analysis Software, Data Center Storage Consolidation Tool Suite, Huawei CloudLink Video Conferencing Platform, One-stop Platform for Marketing Development, City of Stories, Digital Transformation: If multiple SUN2000s need to communicate with one another and are connected to a PC over the SmartLogger2000, a maximum of six daisy chains can be configured. For the other two inverters, it's 98.6%. You still have access to your history but no new orders can be placed. efficiency: 99.03%: European Efficiency : 98.69%: Input: Max. If the Smart Dongle version is SDongle V100R001C00SPC116 or later, the SUN2000-60KTL-M0 can connect to the DTSU666-H smart power sensor to implement power scheduling. A single-phase power meter is recommended for the networking with only single-phase inverters. Stories, Digital Transformation: Hallo Tom (und gerne auch andere )Ich scheitere leider immernoch an der Konfiguration meiner Anlage.Der zweite Sun2000 wird inzwischen via RS485 gefu . SUN2000-100KTL-H0. Europe. The Huawei Sun2000 KTL M1 inverter range includes the Sun2000 5KTL M1, Sun2000 8KTL M1, Sun2000 10KTL M1, and more. There is, however, still surge protection present, for both DC and AC. One-stop Platform for Marketing Development. Some functions of the website may be unavailable. If a device is connected to the RS485_2 port on a SUN2000, the device is not counted as a cascaded device. SUN2000-30/36/40KTL-M3 quick guide . If the SUN2000-(2KTL-6KTL)-L1 are cascaded with three-phase inverters, they must be connected to the grid in the same phase. Smart pv optimizer (52 pages) Media Converter Huawei SUN2000 User Manual. Installation vorbereiten. Ensure that the exposed core is totally inserted into the cable hole. The Huawei SUN2000-3.68KTL-L1 is part of the new range of Huawei single-phase residential hybrid inverters. Huawei FusionSolar provides new generation string inverters with smart management technology to create a fully digitalized Smart PV Solution. Leave your details and we'll be in touch. Looking to make a purchase? Connect the signal connector to the corresponding port. For details about parameter settings, see. A single-phase power meter is recommended for the networking with only single-phase inverters. If the SUN2000- (2KTL-6KTL)-L1 are cascaded with three-phase inverters, they must be connected to the grid in the same phase. Hotline, Branch These inverters differ from each other in their power levels. Related Manuals for Huawei SUN2000-450W-P. Inverter Huawei SUN2000 Series User Manual. Intelligence, 100 Digital Transformation After determining the installation position of the optimizer, remove and attach the SN label. This section describes how to commission the SUN2000 inverters with RS485 communication Modbus-RTU Protocol. Used for connecting to the RS485 signal ports of the battery and smart power sensor. Professionals . If they are changed, meters may go offline, generate alarms, or affect the inverter output power. The preceding networking uses DDSU666-H as an example. 1. . It manages the maximum power point (MPP) of each PV module to improve the energy yield of the. Dimensions (W x H x D) 525 mm × 470 mm × 262 mm (including only the rear mounting kit of the SUN2000) Net weight. Password: "00000a" is not accepted because it is too short. Looking to make a purchase? Page 1 SUN2000-(3KTL-10KTL)-M1 User Manual Issue Date 2020-11-20 HUAWEI TECHNOLOGIES CO., LTD.; Page 2 Notice The purchased products, services and features are stipulated by the contract made between Huawei and the customer. . Leave your details and we'll be in touch. For operations with the SUN2000 APP, see the, If the MBUS (PLC) communication mode is selected, do not connect the RS485 communications cable. From Strategy to Execution, Global Service How do I use the offline download function of ICS Lite? Intelligence, 100 Digital Transformation Stories, Digital Transformation: Page 1 SUN2000-(2KTL-6KTL)-L1 User Manual Issue Date 2020-09-15 HUAWEI TECHNOLOGIES CO., LTD.; Page 2 Notice The purchased products, services and features are stipulated by the contract made between Huawei and the customer. Cable connections for other meter models may vary. The MBUS (PLC) communication board loads communication signals onto power cables for transmission. Office. In the preceding networking, the SUN2000s are cascaded and support the grid-tied point control function to achieve zero export. The implementation of 10 MPPTs reduces string mismatching, because differences in module orientation can be better optimized. If the SUN2000-60KTL-M0 version is SUN2000 V300R001C00SPC116 or later, the RS485_2 port can connect to the DTSU666-H smart power sensor. Your file has been added to the offline download list. Instantly find the answers to all your questions about Huawei products and Do you have a question about the Huawei SUN2000-15KTL-M2 or do you need help? This library is intended for reading Huawei Sun2000 inverter metrics from registers via Modbus TCP. Commercial. MBUS communication is set to Enable by default. Your browser version is too early. Products, Solutions and Services for Enterprise, Smartphones, PC & Tablets, Wearables and More. For the best experience on our site, be sure to turn on Javascript in your browser. Due to the power measurement limit of the DTSU666-H, the current should not exceed 250 A. Commercial Smart Inverter|SUN2000) Document List Support My Support Enter My Support; My Applications Software Requests Case Application Document Applications Product Registration My Product Permissions My To-Do . Europe. indicates a power cable; indicates the power flow direction; indicates a signal cable. Installing the RS485 Communications Cable, (Optional) Installing the Solar Tracker Power Cable. Huawei Inverter SUN2000-100KTL-M1 can manage up to 20 strings, which are all individually and intelligently monitored. Cumpara Invertor hibrid trifazat Huawei SUN2000-10KTL-M1, Wlan, 4G, 10 kW de la eMAG! You can change lines. All or part of the products, services and features described in this document may not be within the purchase scope or the usage scope. Ensure that the signal cables are connected securely. When both battery and smart power sensor are configured, they need be crimped to the 485B2 and 485A2 ports. To obtain better user experience, upgrade the browser to the latest version. Installed between the SUN2000 and tracking control box, Fuse specifications: rated voltage ≥ 800 V; rated current: 6 A; protection: gG, Circuit breaker specifications: rated voltage ≥ 800 V; rated current: 6 A; tripping: C. A PV string is composed of PV modules connected in series. ESTG is a wholesaler of solar inverters and other sustainable electrical products, such as EV chargers, solar batteries and thermal heating. Language |. Its external AC switch should be a three-phase circuit breaker or other AC load circuit breakers to safely disconnect the SUN2000 from the power grid. If multiple SUN2000s are used, connect all the SUN2000s with an RS485 cable in daisy chain mode. The design is free of fuses, but instead uses a so-called RCMU, or a Residual Current Monitoring Unit. Nr. FE communication is optional for the SUN2000-36KTL. Extend the warranty for your Huawei inverter by 10, 15 or 20 years. If you connect a ground cable to the ground point in the maintenance compartment, you are advised to use a four-core (L1, L2, L3, and PE) outdoor cable, M10 OT/DT terminals (L1, L2, and L3), and M8 OT/DT terminals (PE). The inverter can directly connect to the PC over the Ethernet to implement monitoring networking. If multiple SUN2000s need to communicate with one another and are connected to a PC over the SmartLogger1000, a maximum of three daisy chains can be configured. It can be reserved for the feedback signal of the Backup device. This continually monitors the device. This manual is available in the following languages: English. This document describes only the networking diagrams. FE communication is mainly used in distributed rooftop scenarios with a small number of inverters. An error occurred when loading the video. Connecting the RS485 Communications Cable, (Optional) Installing the Power Cable of the Tracking System, SUN2000-(90KTL, 95KTL) Series Technical Data, SUN2000-(100KTL, 105KTL) Series Technical Data. No battery connected: 600 V. LG-RESU battery connected: 495 V. Maximum input current (per MPPT) 12.5 A. sun2000_modbus. Do you want absolute certainty your inverter will remain functional? 2. View the manual for the Huawei SUN2000-15KTL-M2 here, for free. Contact Us: e_online@huawei.com Copyright © 2023 Huawei Technologies Co., Ltd. All rights reserved. Die 12-25KTL Geräte von Huawei haben mit dem Sprung von der M2 auf die M5 Serie genauso ein Update erhalten. 25 kg (including only the rear mounting kit of the SUN2000) Noise. The PE point in the maintenance compartment is used for connecting to the PE cable included in the multi-core AC power cable. Some functions of the website may be unavailable. Hotline, Branch Tabelle 5-1 Beschreibung der Bauelemente. SUN2000-17KTL-M2. In addition, the network management software (such as the NetEco) needs to be installed on the PC for monitoring networking. If the SUN2000-60KTL-M0 version is SUN2000 V300R001C00SPC116 or later, the RS485_2 port can connect to the DTSU666-H smart power sensor. You can change lines. You can change lines. This means that you have deleted the password needed for connection, go to the inverter and turn on the WiFi scan on the phone, when your SUN2000-2050084xxxx inverter pops up, click on it and enter the password provided on the side of the inverter. With a wide range of A-brands, ESTG supplies installers across Europe. The specifications of the PE cable are subject to this table or calculated according to IEC 60364-5-54. Note: Even the most advanced machine translation cannot match the quality of professional translators. Ai libertatea sa platesti in rate, beneficiezi de promotiile zilei, deschiderea coletului la livrare, easybox, retur gratuit in 30 de zile si Instant Money Back. Stay connected! Page 1 SUN2000-(3.8KTL-11.4KTL)-USL0 User Manual Issue Date 2018-05-21 HUAWEI TECHNOLOGIES CO., LTD.; Page 2 Notice The purchased products, services and features are stipulated by the contract made between Huawei and the customer. To obtain better user experience, upgrade the browser to the latest version. PV system, and performs functions such as module-level shutdown and module-level management. If multiple SUN2000s need to communicate with one another and are connected to a PC over the SmartLogger1000, a maximum of three daisy chains can be configured. 29 dB (A) (typical working condition) Operating temperature. The main purpose for this is surely the initial configuration by an installer. The device can intelligently monitor 20 strings, reach an efficiency rating of 98,6% (98,4% European efficiency) at 400Vac, has 10 MPPTs and has various characteristics that make it safe and reliable. This document describes the installation, commissioning, maintenance, and troubleshooting of the SUN2000-250KTL-H1, SUN2000-250KTL-H3, SUN2000-280KTL-H0, SUN2000-300KTL-H0, SUN2000-330KTL-H1, and SUN2000-330KTL-H2 (also referred to as SUN2000). Does the Optimizer Support Partial Configuration Scenarios? The tracking system should be equipped with an overcurrent protective device/component. Please contact your account manager or our customer support team to re-activate your account. Connect signal cables to corresponding signal connectors. Page 2 Notice The purchased products, services and features are stipulated by the contract made between Huawei and the customer. If FE communication is used, a maximum of 10 SUN2000s can be connected. The RS485 and MBUS (PLC) communication modes are mutually exclusive. Community Forums Groups Blog & Collections Rewards FAQ Top Members Subscribe. 17 kg (including only the rear mounting kit of the SUN2000) Noise. Hi there, I hope someone can help me. The SUN2000 communicates with a USB flash drive through the USB port to upgrade firmware, download and load configurations, and download data. The maximum number of devices that can be connected to a Smart Dongle is written in the label on the outer package. I am using the smart dongle Modbus TCIp activated two inverters Sun2000 10ktl m1 the Samar meter and one . ), as well as a shielded RJ45 connector, Three-core outdoor copper cable with dual-layer protection, Conductor Cross-Sectional Area S of the AC Power Cable (mm2), Conductor Cross-Sectional Area SP of the PE Cable (mm2). An error occurred when loading the video. Office. Preferred to connect to the PE point on the enclosure. The smart power sensor and Smart Dongle must be connected to the same SUN2000. ICS Lite is not installed or the software version is too early. • Kommunikation: RS485, Wifi / LAN (optional), 4G / 3G / 2G (optional) • Schutzklasse: IP66 • Kühlung: aktiv • Abmessungen: 460 x 546 x 228 mm (H x B x T) • Gewicht: 21,0 kg *kompatibel mit Huawei Optimierer: SUN2000-450W-P, SUN2000-450W-P2, SUN2000-600W-P, SUN2000-1300W-P, SUN2000-1100W-P. Only one LG battery is supported, and the LG battery must be connected to the inverter equipped with the Smart Dongle. B. AC switch. SUN2000-105KTL-H1 . Utility Scale. Your browser version is too early. Huawei FusionSolar provides new generation string inverters with smart management technology to create a fully digitalised Smart PV Solution. solutions. Can be purchased from Huawei. Huawei Enterprise Support Community. No relevant resource is found in the selected language. If FE communication is used, set Ethernet and Management system for the SUN2000 on the SUN2000 APP. SUN2000-(29.9KTL, 33KTL-A, 36KTL, 42KTL) User Manual. FTKastner (Friedrich Kastner) May 30, 2023, 11:37am #1. Intelligence, 100 Digital Transformation . If the Smart Dongle version is SDongle V100R001C00SPC116 or later, the SUN2000-60KTL-M0 can connect to the DTSU666-H . Manual will be automatically added to "My Manuals", Installed on an Extruded Aluminum Profile – T-Shaped Bolt, Installed on a PV Module Frame – Bolt Assembly, Installed on a PV Module Frame – Frame Mounting Bracket. If the SUN2000 is networked using the SDongleA-03 (4G, Smart Dongle for short), it cannot be connected to the SmartLogger. The Huawei Inverter SUN2000-100KTL-M1 is a smart, efficient, safe and reliable inverter for commercial use. Huawei uses machine translation combined with human proofreading to translate this document to different languages in order to help you better understand the content of this document.
Mydhl+ Plus Abholung Buchen,
Schlaganfall Nicht Erkannt,
Articles H